Site icon ZipTuning

SPN 4094 – NOx limits exceeded due to insufficient DEF quality

Introduction

Fault Code SPN 4094 is a generic diagnostic trouble code (DTC) that indicates the NOx (nitrogen oxide) limits have been exceeded in the exhaust system. This code commonly appears on heavy-duty trucks and buses equipped with diesel engines and SCR (Selective Catalytic Reduction) aftertreatment systems. When SPN 4094 is triggered, the vehicle may enter a derated mode, limiting engine power and speed. While it's possible to continue driving for a short distance, it's recommended to diagnose and address the issue promptly to avoid further damage and downtime[.

In our workshop, we've encountered the SPN 4094 fault code quite frequently, especially on European makes like Volvo, Mack, and Mercedes-Benz trucks. Just last week, a 2012 Volvo came in with SPN 4094 FMI 18, along with some other codes related to the aftertreatment system. We went through the usual diagnostic steps – checking the DEF quality, inspecting the dosing valve, and evaluating the NOx sensors. After replacing a faulty NOx sensor and performing a forced DPF regen, the code cleared but returned a few days later. It's a frustrating issue that often seems to come back, even after repairs. From what I've seen on the forums, many other shops are dealing with the same problem on these European trucks. Some have had luck replacing the DEF dosing valve or cleaning the EGR ports, but it's not always a guaranteed fix. SPN 4094 definitely keeps us on our toes, and it takes persistence to get to the bottom of it.

Understanding SPN 4094

SPN 4094 specifically points to the NOx levels in the exhaust exceeding the allowable limits set by the engine control module (ECM). The ECM continuously monitors the NOx sensors before and after the SCR catalyst to determine if the aftertreatment system is operating efficiently. If the downstream NOx sensor detects levels above the threshold, SPN 4094 is triggered[.

This fault code is considered generic across all heavy-duty vehicles equipped with J1939 protocol. However, the exact NOx limits and derate conditions may vary slightly between different engine manufacturers[.

Parts Involved:

Common Causes

Some of the most frequent causes of SPN 4094 include:

Buy tested tuning file for Adblue / EGR / DPF / Adblue off now!

Register Now or Already have an account,
  1. Degraded or contaminated DEF fluid
  2. Faulty DEF injector or dosing issues
  3. Blocked or damaged SCR catalyst
  4. NOx sensor failures
  5. Exhaust leaks before the SCR system
  6. Low DEF fluid levels
  7. Issues with the DEF supply system (pump, lines, filter)[

Diagnosis

To properly diagnose SPN 4094, follow these steps:

  1. Scan for all active fault codes. Note any other codes present, especially those related to the aftertreatment system.
  2. Check DEF fluid level and quality. Ensure the fluid is clear and not past the expiration date.
  3. Perform a DEF quality test using a refractometer. DEF should have a urea concentration between 31.8-33.2%.
  4. Inspect the DEF injector for proper spray pattern and flow rate. Clean or replace as needed.
  5. Perform a NOx sensor evaluation to check accuracy and response times. Replace faulty sensors.
  6. Check for any exhaust leaks before the SCR system which could allow unmetered air to enter.
  7. Evaluate SCR catalyst for signs of damage or blockage.
  8. Verify proper function of the DEF pump and supply lines. Repair any leaks or restrictions.

Tools Needed:

Repair Solutions

After identifying the root cause, perform the following repairs as needed:

In many cases, the repairs can be performed by a skilled mechanic. However, always consult the manufacturer's service information for specific procedures and torque specifications. Replacing major components like the SCR catalyst or DEF injector may require specialized tools and should be left to a dealership technician.

Repair Costs

The cost to repair issues causing SPN 4094 can vary widely depending on the root cause and specific vehicle.

Labor costs can range from $100-175 ($90-160 Euro) per hour, with most repairs taking 2-8 hours depending on the issue and accessibility.

Prevention

To help prevent SPN 4094 issues:

Associated Codes

Other fault codes that frequently appear alongside SPN 4094 include:

These codes often point to underlying issues with the DEF system, NOx sensors, or SCR catalyst that are causing the high NOx levels indicated by SPN 4094.

Frequently Asked Questions About SPN 4094

What is SPN 4094?

SPN 4094 is a generic diagnostic trouble code (DTC) that indicates the NOx (nitrogen oxide) levels measured in the exhaust have exceeded the acceptable limits set by the engine control module (ECM).

What are the symptoms of SPN 4094?

When SPN 4094 is triggered, the most common symptoms include:

Is it safe to keep driving with SPN 4094?

While it’s possible to continue driving for a short distance when SPN 4094 appears, it’s recommended to diagnose and address the issue promptly to avoid further damage and downtime. Ignoring the code can lead to more severe engine derates.

What are the common causes of SPN 4094?

Some of the most frequent causes of SPN 4094 include:

  1. Degraded or contaminated DEF fluid
  2. Faulty DEF injector or dosing issues
  3. Blocked or damaged SCR catalyst
  4. NOx sensor failures
  5. Exhaust leaks before the SCR system
  6. Low DEF fluid levels
  7. Issues with the DEF supply system (pump, lines, filter)

Is SPN 4094 specific to certain engine makes?

SPN 4094 is considered a generic code across all heavy-duty vehicles equipped with a J1939 communication protocol. However, the exact NOx limits and derate conditions may vary slightly between different engine manufacturers.

What parts are involved with SPN 4094?

The main components related to SPN 4094 are:

How do you diagnose the root cause of SPN 4094?

To properly diagnose SPN 4094, follow these steps:

  1. Scan for all active fault codes and note any others present
  2. Check DEF fluid level and quality
  3. Perform a DEF quality test using a refractometer
  4. Inspect the DEF injector for proper spray pattern and flow rate
  5. Perform a NOx sensor evaluation
  6. Check for exhaust leaks before the SCR system
  7. Evaluate SCR catalyst for signs of damage or blockage
  8. Verify proper function of the DEF pump and supply lines

What tools are needed to diagnose SPN 4094?

The main tools required for SPN 4094 diagnosis include:

How do you fix issues that cause SPN 4094?

After identifying the root cause, perform the necessary repairs:

Can SPN 4094 repairs be done by a mechanic or is a dealer required?

In many cases, the repairs can be performed by a skilled mechanic. However, always consult the manufacturer’s service information for specific procedures. Replacing major components like the SCR catalyst or DEF injector may require specialized tools and should be left to a dealership technician.

How much does it cost to repair SPN 4094 issues?

The cost to repair issues causing SPN 4094 can vary widely depending on the root cause and specific vehicle. Some common costs include:

Labor costs can range from $100-175 ($90-160 Euro) per hour, with most repairs taking 2-8 hours.

How can you prevent SPN 4094 from occurring?

To help prevent SPN 4094 issues:

What other fault codes commonly appear with SPN 4094?

Other codes that frequently appear alongside SPN 4094 include:

These codes often point to underlying issues with the DEF system, NOx sensors, or SCR catalyst that are causing the high NOx levels indicated by SPN 4094.

Can a bad turbocharger cause SPN 4094?

Yes, a faulty turbocharger or VGTA (variable geometry turbocharger actuator) can lead to SPN 4094. If the turbo is not functioning properly, it can cause incomplete combustion and higher NOx production. This will make it difficult or impossible to perform a DPF regen.

Can cold weather trigger SPN 4094?

Cold temperatures can sometimes cause SPN 4094 to appear if there are underlying issues with the aftertreatment system. Extremely low temperatures can cause the DEF to freeze in the lines or crystallize in the injector, leading to insufficient DEF dosing and higher NOx levels.

What does FMI 18 mean on SPN 4094?

FMI (Failure Mode Indicator) 18 on SPN 4094 indicates the data is valid but below normal operating range. In this case, it points to the NOx levels being higher than the acceptable threshold set by the ECM.

Will a DPF delete or SCR delete fix SPN 4094?

While a DPF or SCR delete may temporarily eliminate SPN 4094, it is illegal in most regions and can lead to significant fines and penalties. Deleting emissions control devices also increases harmful pollutants and can cause engine damage over time. It is always recommended to diagnose and repair the root cause of SPN 4094 rather than deleting components.

Can bad DEF fluid quality cause SPN 4094

?

Absolutely, using contaminated, expired, or diluted DEF fluid is one of the most common causes of SPN 4094. The ECM monitors fluid quality using the NOx sensors and will trigger the code if the conversion efficiency drops due to poor DEF quality. Always use API certified DEF fluid from a trusted supplier and follow proper storage and handling practices.

Can a cracked or leaking DEF injector cause SPN 4094?

Yes, a cracked DEF injector can lead to SPN 4094 by allowing exhaust gases to leak into the DEF system. This contaminates the fluid and leads to crystallization that clogs the injector. A cracked injector can also cause the DEF to drip into the exhaust stream when not commanded, causing ammonia odors and inaccurate dosing.

Will SPN 4094 clear itself once the repair is made?

In most cases, SPN 4094 will not automatically clear after repairs are completed. The code will need to be manually cleared using a diagnostic scan tool. In addition, a forced DPF regen or series of regens may need to be performed to restore proper aftertreatment function and efficiency before the code will remain cleared.

The key to addressing SPN 4094 is thorough diagnosis to identify all the contributing factors and then performing the necessary repairs. Overlooking issues or making quick fixes will often lead to repeat failures. When in doubt, consult the manufacturer’s service information or contact a dealer technician for assistance.